  1. Service Repair Manuals

HS 20-65 Booster Pump Systems with Torrium 2 Data Brochure and Catalog. HS Series Booster Pump Systems Installation and Operating Instructions Guide. Homepage for Davey Water Products with information about Davey and where to buy Davey products. Fire emblem akatsuki no megami.

Priming and Operation 1. Fill pump and suction line (on flooded suction, simply open gate valve to pump). When full, fit Supercell Pressure Tank or Priming Plug as applicable. Ensure outlet nearest to pump is open. Ensure all valves in suction line are open and switch on. Prime should establish almost immediately and a strong flow of water should be evident from the outlet.

They are familiar with Davey products specifically and don't just have most products on hand, but also the necessary fittings and accessories to ensure you have everything you need. Master Dealers are our experts in the field to provide you with the right direction and advice for your next project or Davey purchase. Find your nearest Davey Master Dealer.

I'm turning it off overnight for now to save any extra problems developing. I do think the bloke at the shop knows his stuff but. Any other suggestions? You problem is the 'foot valve' at the bottom of the well is worn or has some dirt/debris in the sealing face and allowing the water to flow back into the well overnight when the pump is not keeping the pump and well pipe full of water. They are non replaceable being they are at the bottom of the well, hence the name 'foot valve'.

Maintenance The only regular attention your new pressure system requires is to check the pressure tank’s air charge every 6 months. This can be checked at the air valve with a tyre gauge. Do not charge tank to a higher pressure than 168kPa (XJ Ultra) or 196kPa (XJ70P & XJ90P). To check air pressure in tank: 1.

Just took my pump in because it was taking ages for the pressure to get up. We though maybe it was the capacitor which was replaced last year. I'd already tried pumping it up to the required 19psi with a bicycle pump. It was neither of these things but it came back working a treat and cost me $120 for the job. Fair enough I suppose. However, now the pump keeps switching on every minute and a half for 3 or 4 seconds. The fella at the shop reckons it could be a 'leak' somewhere affecting the water pressure, but there are no (apparent) leaks.

Service manual troy-bilt

Y ou ar e also entitled to have the goods r epair ed or r eplaced if the goods fail to be of acceptable quality and the failur e does not amount to a major failur e. Should your Davey pr oduct r equir e r epair or service after the guarantee period; contact your near est Davey Dealer or phone the Davey Customer Service Centr e on the number listed below. For a complete list of Davey Dealers visit our website (davey.com.au) or call: * Installation and operating instructions ar e included with the pr oduct when pur chased new. They may also be found on our website. P/N 48661-8 supersedes P/N 48661-7 AUSTRALIA Customer Service Centr e 6 Lakeview Drive, Scor esby, Australia 3179 Ph: 1300 367 866 Fax: 1300 369 119 W ebsite: davey.com.au Davey W ater Pr oducts Pty Ltd Member of the GUD Gr oup ABN 18 066 327 517 NEW ZEALAND Customer Service Centr e 7 Rockridge A venue, Penr ose, Auckland 1061 Ph: 0800 654 333 Fax: 09 527 7654 W ebsite: daveynz.co.nz ® Davey & Dynajet ar e r egister ed trade marks of Davey W ater Pr oducts Pty Ltd.

Switch off pump. Open outlet nearest to pump to release water pressure. Remove air valve cap from top of Supercell tank and charge tank to 168kPa (XJ Ultra) or 196kPa (XJ70P & XJ90P) using air pump and check with tyre gauge. Close outlet. Please pass these instructions on to the operator of this equipment.

Mechanical seals, bearings or capacitors), loss or damage r esulting fr om misuse or negligent handling, impr oper use for which the pr oduct was not designed or advertised, failur e to pr operly follow the pr ovided installation and operating instructions, failur e to carry out maintenance, corr osive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons attempting r epairs. Wher e applicable, your Davey pr oduct must only be connected to the voltage shown on the nameplate. Your Davey T wo Y ear Guarantee does not cover fr eight or any other costs incurr ed in making a claim. Please r etain your r eceipt as pr oof of pur chase; you MUST pr ovide evidence of the date of original pur chase when claiming under the Davey T wo Y ear Guarantee. Davey shall not be liable for any loss of pr ofits or any consequential, indir ect or special loss, damage or injury of any kind whatsoever ar ising dir ectly or indir ectly fr om Davey pr oducts. This limitation does not apply to any liability of Davey for failur e to comply with a consumer guarantee applicable to your Davey pr oduct under the Australian or New Zealand legislation and does not af fect any rights or r emedies that may be available to you under the Australian or New Zealand Consumer Legislation. In Australia, you ar e entitled to a r eplacement or r efund for a major failur e and for compensation for any other r easonably for eseeable loss or damage.

Valve on suction lines closed. B) PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING) - Pressure Pumps Only 1. Check that tank air pressure is correct - see above. Leaking taps, float valves etc. Check plumbing. Leaking check valve/foot valve. C) MOTOR DOESN’T START WHEN SWITCHED ON.

DAVEY XP500H AUTO WATER PUMP Davey XP 500H Constant Pressure Household Pump • Up to 53 litres/min • 20 PSI • Runs 4 taps • 'Hydrascan' control system maintains pressure at constant level Operating Limits: Max capacity: 53lpm Total head: 30m Cut in Pre.: 150kPa = 20kPa Min setting: 120 kPa Max setting: 550kPa Cut-out flow rate: 2lpm Max liquid temp.: 50 degree C Max ambient temp.: 55 degree C Max suction lift: 7m Inlet size: 1 ¼” BSP(F) Outlet size: 1” BSP(F) Features & Benefits: Hydrascan CL controlled with adjustable cut-in-presure, LED status light and anti-scaling system. • Reduces pump cycling • Protected against dry running • Fail safe water over-temperature back-up for added peace of mind • Easy to install in high static head situation • Can be used with varying quality water • Easy to trouble shoot Electrical Data XP500H Supply voltage: 220-240v Supply frequency: 50Hz Input power (P1): 0.83kW Output power (P2): 0.6kW Full load current: 3.5A Locked rotor current: 12A Starting: P.S.C. Insulation class: Class F IP rating: 55 Speed: 2 pole, 2850 rpm.

© Davey W ater Pr oducts Pty Ltd 2011.

Allow water to flow for 10-20 seconds to expel air then close outlet. Automatic Pressure Pumps will shut down automatically within several seconds. Manual systems must be switched off at the power point. If no flow is evident from tap, switch off at power point and repeat from step 1 ensuring there is an adequate supply of water available to the pump. Never operate your Davey Dynajet ® pump for more than a few seconds without discharge flow. Robokill 2 full game unblocked. *NOTE: For protection, the Davey pump motor is fitted with an automatic “over temperature” cut-out. Constant tripping of this overload device indicates a problem eg.

If you are in need of perfect pressure, healthy drinking water, protection from fire or flood, or a clean, relaxing pool or spa Davey have solutions that are right for you. Master Dealers You'll find Davey products at an extensive network of dealers across Australia and New Zealand. Davey’s extensive Master Dealer network represents businesses with a broad product offering, the local knowledge and experience you can rely on and servicing capabilities for post-purchase peace of mind.

You can correct that problem by the addition of a check valve above ground installed in the suction pipe of the pump, be sure it is a spring loaded device so that you can install it in any position. Another way to keep the pump primed is to feed a small amount of pressurized water into the pump all night, you can do this by the addition of a connection to where the pressure gauge connects to the pump. Please take time to rate me Aug 31, 2011 .

Low voltage at pump, excessive temperature (above 45 o C) in pump enclosure. Care should also be taken when servicing or disassembling pump to avoid possible injury from hot pressurised water. Unplug pump, relieve pressure by opening a tap on the discharge side of the pump and allow any hot water in the pump to cool before attempting to dismantle. During servicing, use only approved, non-petrochemical based oring and gasket lubrication. If unsure, consult your Davey Dealer for advice.

A jammed impeller. Internal motor fault.

NOTE: Prior to installation remove the red transport plugs from the suction and/or discharge. In accordance with AS 3350.2.41 we are obliged to inform you that this pump is not to be used by children or infirm persons and must not be used as a toy by children. Davey ® Repair or Replacement Guarantee In the unlikely event in Australia or New Zealand that this Davey pr oduct develops any malfunction within two years of the date of original pur chase due to faulty materials or manufactur e, Davey will at our option r epair or r eplace it for you fr ee of char ge, subject to the conditions below. Should you experience any difficulties with your Davey pr oduct, we suggest in the first instance that you contact the Dav ey Dealer fr om which you pur chased the Davey pr oduct. Alter natively you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the addr ess listed below. On r eceipt of your claim, Davey will seek to r esolve your difficulties or, if the pr oduct is faulty or defective, advise you on how to have your Davey pr oduct r epair ed, obtain a r eplacement or a r efund. Your Davey T wo Y ear Guarantee naturally does not cover normal wear or tear, r eplacement of pr oduct consumables (i.e.

XP500H, XP700H & XP900H PRESSURE SYSTEMS WITH XP500H, XP700H & XP900H PRESSURE SYSTEMS WITH HYDRASCAN CL ® CONTROL Model Numbers: 72211, 72311 & 72411 Note: Also available in 220V 60Hz single phase and 110V 60Hz single phase.

WARNING: When servicing or attending pump, always ensure power is switched off and lead unplugged. Electrical connections should be serviced only by qualified persons. WARNING: Do not use hydrocarbon based or hydrocarbon propelled sprays around the electrical components of this pump.

“Over temperature” cut-out tripped.* 4. Motor not free to turn eg.

Power not connected. Supply voltage too low.

Installa tion and Oper ating Instr uctions for Dynajet ® XJ Ultr a/XJ70P/XJ90P Pr essur e Pumps & XJ50/XJ70/XJ90 Electric Pumps Trouble Shooting Check List a) MOTOR RUNS WHEN SWITCHED ON BUT DOES NOT PUMP. Suction line and pump body not filled with water. Air leaks in suction lines or suction pipe not under water. Air trapped in suction lines (also possible with flooded suction due to uneven rise in piping; eliminate humps and hollows). No water at source or water level too low.

Service Repair Manuals

About davey Davey is Australia and New Zealand's international water products company. Davey Water Products designs, builds and sells products for transfer, conservation, treatment and filtration of water. Davey is recognised for quality brands such as,,,,,,,,,,,,, and PoolSweepa. Consider Davey for water pumps, borehole pumps, firefighter pumps, drainage pumps, UV treatment systems, filtration and pool and spa equipment.